ENGLISH 简体中文 日本語 한국어  


APPLICATION NOTE 2011

High-Side Positive Current Sensor Monitors Negative Supply

Abstract: This application note uses a high-side current-sense amplifier to monitor the current from a negative supply voltage. The circuit uses the IC's wide common-mode input range to amplify a small Vsense signal at the negative supply and level shift it up to a positive output voltage.

All dedicated current-sense amplifiers are designed for high-side sensing on a positive supply, but you can adapt them to monitor a negative supply (Figure 1). The positive supply pin (V+) connects to the system's positive supply, and the ground pin (GND) connects to the negative supply (VEE). That arrangement monitors the negative supply while providing a positive output voltage for the external interface (typically an A/D converter). The RS+ pin of the current-sense amplifier (U1) connects to the load, and the RS- pin connects to the negative supply.

Figure 1. Connecting this positive-supply-current monitor (U1) as shown lets it monitor a negative current while generating a positive output voltage for the ADC.
Figure 1. Connecting this positive-supply-current monitor (U1) as shown lets it monitor a negative current while generating a positive output voltage for the ADC.

U1's current-source output drives a current that is proportional to load current flowing to ground (not to the GND pin). Output resistor RO converts the current to a voltage, which is then digitized by an ADC (optional):



The maximum output voltage is limited by saturation in the internal transistors (which occurs at approximately V+ -1.2V). Thus, V+ must exceed the full-scale output by at least 1.2V. If, for instance, the full-scale output is 1V, then V+ ≥ +2.2V. To meet the device's maximum and minimum operating voltages, 0 ≥ VEE ≥ -(32 - V+) and (V+ - VEE) ≥ +3V. Figure 2 shows the variation of current-measurement accuracy with load current.

Figure 2. The Figure 1 current-sensing error varies with load current as shown.
Figure 2. The Figure 1 current-sensing error varies with load current as shown.

We Want Your Feedback!


Automatic Updates
Would you like to be automatically notified when new application notes are published in your areas of interest? Sign up for EE-Mail™.



More Information  APP 2011: Jun 20, 2003
MAX4172 Low-Cost, Precision, High-Side Current-Sense Amplifier Full Data Sheet
(PDF, 96kB)
Free Samples
 

Download, PDF FormatDownload, PDF Format (33kB)
 AN2011, AN 2011, APP2011, Appnote2011, Appnote 2011


      Privacy Policy    Legal Notices

      Copyright © 2008 by Maxim Integrated Products, Dallas Semiconductor